Motor Data Calculator For Woodworking Machinery
Calculate: Full-Load Amps, Wire Size, Fuse Rating & Circuit-Breaker Size for Single and 3-Phase Motors
KW to HP Converter
Three Phase
| Full Load Amps | 2.5 |
| Wire size | 14 |
| Time Delay Fuse Rating | 4 |
| Circuit Breaker Size | 7 |
Single Phase
| 115 V | 230 V | |
|---|---|---|
| Full Load Amps | 4.4 | 2.2 |
| Wire size | 14 | 14 |
| Time Delay Fuse Rating | 7 | 3.5 |
| Circuit Breaker Size | 7 | 7 |